top of page
AMBU Automation Breathing Device

AMBU Automation Breathing Device

The U-Vent, AMBU or any standard breathing balloon is designed to automatically control you and perform invasive and non-invasive breathing.

U-Vent has a very sensitive mechanical system working with DC motor. Thanks to the sensitive position control sensors, the breathing is realized by squeezing and releasing the AMBU at the determined rates. There are 1 pressure sensor and two flow sensors in the device to control the gas flow, volume and pressure. Thanks to these sensitive sensors, the breathing process is precisely controlled.

U-Vent can optionally be used with an air-oxygen mixer. The desired oxygen rate can be adjusted in 10% slices.

U-Vent has a sensitive and large touch control screen in the size of 10". This
Device settings, graphics and real-time respiratory values can be read from the screen.

Respirator, ventilator device, ambu automation, ventilation, respirator

 

 

  • Technicial Specifications

    U-Vent is designed to be hung on the side barriers of patient beds, thanks to the hanger apparatus  that can be attached and removed from the back of the device.  Suspension apparatus  can be simply attached and detached by hand with no tools 

  • Safe breathing automation

    .
    The U-Vent AMBU has a protective cover made of transparent plexiglass for safety.
    Thanks to the transparent structure of the cover, the operation of the system can be easily observed from the outside.
    This cover prevents foreign matter from entering the work area, also interferes with AMBU 
    in order to prevent
    they were designed.
    In an emergency, the cover can be opened easily, allowing manual intervention.





     

  • Technical document


    Control :
    Screen:
    Ventilation modes:
    Real-time values:
    Ventilation parameters:
    Network connection:
    FiO2:
    Graphics:
    Alarms:
    PLC
    Oxygen - Air mixer (21-100%) (optional)
    Respiratory rate 10-30 breaths/minute
    Inspiration / Expiration ratio 1:1-
    Inspiratory pause  %0-50%
    VCV (Volume Control Ventilation)
    plateau pressure
    Tidal Volume 100ml - 1000ml
    10" touchscreen


















    PCV (Pressure Control Ventilation)
    A/CV (Assist/Control Ventilation) (optional) CPAP (Non-Invasive) (optional)
    1:3



    Minimum airway pressure
    Pause time (0-50% Ti)


    Tidal volume
    Maximum inspiratory pressure Plateau pressure
    Minimum airway pressure
    Volume Pressure Flow
    Pressure limitation 10-60 cmH2O PEEP pressure 3-20 cmH2O High tidal volume
    Low tidal volume Low airway pressure High airway pressure Apnea
    Ethernet TCP/IP
     







bottom of page