top of page
T - TRACK ENVIRONMENT

T - TRACK ENVIRONMENT

T - TRACK ENVIRONMENT

 

  • Designed for use in neonatal intensive care units, delivery rooms and operating rooms
  • Easy to use, functionality and high performance
  • T-Piece Revitalizer provides an easy-to-use and reliable application in Intensive Care Units, Patient Transport, Operation Rooms, Postnatal Services and Delivery Rooms.
  • The use of T-Piece Resuscitation is recommended according to the resuscitation rules. By providing a controlled PIP (Peak Inspiratory Pressure) and accordingly sending the PEEP (Positive Expiratory Pressure) pressure consistently, the patient's lung volume and FRC (Functional Residual Capacity) are increased.
  • Use with mask and tracheal tube

It is an excellent option for accurate and controlled resuscitation of newborns in the emergency room, delivery rooms, transport vehicles and NICU. Conventional ambular and anesthesia ambulars are widely used for resuscitation in hospitals, but they can cause barotrauma or inadequate ventilation in neonates.

Conventional ambulars require an oxygen chamber to deliver high concentrations of oxygen and cannot provide free-flowing oxygen from the mask and do not allow adjustment of PEEP. In the Easypuff neonatal resuscitation unit, the maximum pressure can be adjusted with the maximum pressure relief valve (pop-off valve).

 

#NeoPuff #Fisher&Paykel Neopuff #Babypuff T-piece Refreshing #Easypuff

  • T Piece Revitalizer

    • Designed for use in neonatal intensive care units, delivery rooms and operating rooms
    • Easy to use, functionality and high performance
    • T-Piece Revitalizer provides an easy-to-use and reliable application in Intensive Care Units, Patient Transport, Operation Rooms, Postnatal Services and Delivery Rooms.
    • The use of T-Piece Resuscitation is recommended according to the resuscitation rules. By providing a controlled PIP (Peak Inspiratory Pressure) and accordingly sending the PEEP (Positive Expiratory Pressure) pressure consistently, the patient's lung volume and FRC (Functional Residual Capacity) are increased.
    • Use with mask and tracheal tube
  • Specification of Baby Revitalizer

    Model AD3000-TPB
    flow 0-15LPM
    FiO2 21%-100%
    alarm activation Gas pressure difference>0.1MPa
    pressure gauge -2-10kPa(-20-100cmH2O)
    PIP @5 LPM,2-27cmH2O
    @8 LPM,4-36cmH2O
    @10 LPM, 6-42 cmH2O
    @15 LPM,12-57cmH2O
    CPCP/PEEP @5 LPM,0.3-6cmH2O
    @8 LPM,0.8-14cmH2O
    @10 LPM,1-17 cmH2O
    @15 LPM,2.5-23cmH2O
    noise ≤50dB(A)
    Gas source 0.3MPa-0.4MPa
    Recommended patient weightUp to 10KG  
  • Baby Refreshing

    Baby Booster  Working Principle


    Neonatal resuscitation, also known as neonatal resuscitation, is an emergency procedure that focuses on supporting the approximately 10% of newborns who do not begin to breathe easily, putting them at risk for irreversible organ injury and death. Through positive airway pressure and, in severe cases, chest compressions, medical staff can often alert newborns to begin breathing on their own once the heart rate has normalized. The infant resuscitator can provide a more controlled and consistent peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP) that helps protect the newborn's lungs. The T-Piece Revitalizer is equipped with a built-in air oxygen mixer that can monitor gas flow and FiO2.